Evaluasi Kriteria Penerimaan Sampel Beton Berdasarkan SNI 2847:2019 Pada Proyek Pembangunan Pembangkit Listrik Tenaga Uap
DOI:
https://doi.org/10.25170/jpk.v3i05.8090Keywords:
compressive strength, SNI 2847:2019, ACI 214R-11, quality controlAbstract
Concrete is the primary construction material in power plant infrastructure; therefore, its quality must comply with the acceptance
criteria specified in SNI 2847:2019. This study aimed to evaluate concrete compressive strength test results based on the acceptance criteria of SNI 2847:2019 and to assess the effectiveness of quality control using ACI 214R-11 in the Sorong (Ex-Timika) 4×7 MW Steam
Power Plant construction project. A quantitative descriptive-evaluative method was applied using 28-day concrete compressive strength data for design strengths of 15 MPa, 25 MPa, and 30 MPa. The analysis included descriptive statistics, evaluation of Acceptance Criteria 1 and 2, Z-score analysis to identify weak spots, and standard deviation assessment based on ACI 214R-11. The results showed that all concrete samples satisfied the acceptance criteria with a 100% compliance rate, no weak spots were identified, and all standard deviation values were classified as Excellent. These findings indicate that the project's concrete quality control system effectively ensured compliance with structural quality requirements and supported the reliability of the power plant structure.
References
Aditya, R., & Nugraha, A. (2021). Analisis Kriteria Penerimaan Kuat Tekan Beton Berdasarkan Standar Mutu Konstruksi Nasional. Jurnal Teknik Sipil dan Infrastruktur, 9(2), 112 – 125.
ACI Committee 214. (2011). Guide to evaluation of strength test results of concrete (ACI 214R-11). (http://www.concrete.org). Diakses tanggal 12 Januari 2026.
Badan Standardisasi Nasional. (2019). Persyaratan beton struktural untuk bangunan gedung dan penjelasan (SNI 2847:2019). (http://www.bsn.go.id). Diakses tanggal 15 Februari 2026.
Chandra, S., & Setiawan, B. (2022). Penerapan Metode Moving Average dalam Evaluasi Kontrol Kualitas Beton Mutu Tinggi. Media Komunikasi Teknik Sipil, 28(1), 45 – 54.
Kurniawan, H. (2023). Analisis Keandalan Material Fondasi. Dalam Wibowo, A. (Ed.), Infrastruktur Pembangkit Listrik: Prinsip Dasar Rekayasa Struktur Berbasis Integrasi Material, Mekanika dan Teknik (pp. 145-178). Jakarta: Penerbit Universitas Katolik Indonesia Atma Jaya.
Mehta, P. K., & Monteiro, P. J. M. (2014). Concrete: Microstructure, Properties, and Materials (4th ed.). McGraw-Hill Education.
Neville, A. M. (2011). Properties of Concrete (5th ed.). Harlow: Pearson Education Limited.
Nugroho, S. A. (2020). Evaluasi Statistik Kendali Mutu Beton pada Proyek Infrastruktur Energi. Jurnal Rekayasa Sipil, 16(2), 89 – 98
Pratama, D., & Wijaya, I. (2022). Pengaruh Logistik Antarpulau terhadap Konsistensi Mutu Agregat dan Campuran Beton Ready-Mix. Prosiding Seminar Nasional Infrastruktur Kebangsaan (pp. 112 – 120). Makassar: Universitas Hasanuddin
Santoso, T., & Utomo, B. (2021). Aplikasi Metode Z-Score dalam Deteksi Anomali Distribusi Kuat Tekan Beton Lapangan. Jurnal Standardisasi Infrastruktur, 14(3), 201 – 215.
Suryani, L., & Pratama, M. R. (2024). Pengujian Non-Destruktif dan Evaluasi Titik Lemah Struktural pada Beton Komponen Kritikal. Jurnal Praktik Keinsinyuran, 11(1), 67 – 78.
Triwulan, T., & Wahyudi, R. (2018). Efek Fluktuasi Termal Lingkungan terhadap Variabilitas Kuat Tekan Silinder Beton Lapangan. Prosiding Konferensi Nasional Teknik Sipil (pp. 89 – 97). Jakarta: Universitas Indonesia.
Wibowo, A., & Kusuma, H. (2023). Pengendalian Mutu Beton Massa Makro pada Struktur Fondasi Berat Infrastruktur Strategis. Jurnal Teknik Sipil dan Bangunan, 20(1), 34 – 48.
Yulianto, E. (2021). Manajemen Kendali Mutu (Quality Control) pada Fabrikasi Massal Beton Ready-Mix. Surabaya: Penerbit Politeknik Press.
American Concrete Institute (ACI) Committee 318. (2019). Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary. Farmington Hills: American Concrete Institute